Quietside QS12-VJ220 User Manual

Browse online or download User Manual for Split-system air conditioners Quietside QS12-VJ220. QS012-VJ VP 220 SUBMITTAL A

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Electro-static, washable, main filter as standard
Low ambient control built in
The outdoor unit shall supply power to the indoor unit
Construction
The outdoor unit shall be galvanized steel with a baked on
powder coated finish for durability
The indoor shall have a UL94 V0 chassis with galvanized steel
mounting bracket
Heat Exchanger
The heat exchanger shall be mechanically bonded fin to copper
tube.
Controls
The unit shall be operated via communication through high
voltage.
14AWG X 4 interconnect wire between condenser and
evaporator.
Evaporator ships with wireless controller as standard.
Refrigerant Sy
stem
The refrigerant shall be R410A
The compressor shall be a hermetically sealed, inverter
controlled, Twin BLDC Rotary type.
Refrigerant flow shall be controlled by EEV (electronic expansion
valve) at outdoor unit.
Indoor Fan
Indoor fan is a single, crossflow type
Four speed settings and auto setting
noitacoLemaN boJ
reenignEresahcruP
noitcurtsnoClavorppAecnerefeRot dettimbuS
# eludehcSnoitangiseD tinU
Cooling (Btu/h)
Heating (Btu/h)
Condensate Pints/hour
Voltage (ø/V/Hz)
Cooling
Heating
Max Breaker Amps
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Type
FPI
Pipe Diameter
Indoor Unit
Cooling
F
Heating
F
High side
Low side
Factory Charge oz.
Additional Refrigerant
RLA Amps
L.R.A. Amps
RLA Amps
Air Volume CFM
Output W
RLA Amps
Warranty
Samsung and Quietside maintains a policy of ongoing development, specifications are subject to change without notice.
*Nominal heating capacities are based on: Indoor temperature: 70
F DB, 60 F WB. Outdoor temperature: 47F DB, 43 F WB.
*Nominal cooling capacities are based on: Indoor temperature: 80
F DB, 67 F WB. Outdoor temperature: 95F DB, 75 F WB.
Compressor
Wall Bracket
Safety Certifications
Accessories
Line Sets
Insulated and flared,
interconnect cable
included
Evaporator Fan
Type
Condenser Fan
Motor
Condensate pump
Type
Refrigerant
Type
Control Method
Charged for
Pipe
Connections
Indoor &
Outdoor
Maximum Line Set Length
Maximum Vertical Separation
Sound Pressure
Level
(dB)
Outdoor Unit
Operating
Temperatures
Heat Exchanger
Indoor &
Outdoor Unit
Dimensions
W X H X D
(Inches)
Weight (lbs.)
Condensate Connection
Power
Rated Current
(amps)
Min. Circuit Ampacity
Specifications
Performance*
Nominal
Capacity*
SEER / EER
HSPF
Model
Indoor Model Number
Outdoor Model Number
SUBMITTAL
Page
3100 - 13000
2400 - 14000
20 / 14.2
9.2
3
1 / 220 / 60
4.5
5.2
15
10 A
33 1/4 X 10 7/8 X 7
29
91
11/16" OD
Aluminum Fin - Copper Tube
19
7.25mm indoor / 3/8" outdoor
SH/H/M/L
44 / 39 / 36 / 33
52
0.4
T 109
-5
T 75
1/4"
3/8"
66 feet
33 feet
R410A
Electronic Expansion Valve
46.00
25 feet
0.7 oz/ft over 25 feet
DC, Inverter Driven, Twin Rotary
6.47
-
Crossflow (1)
0.2
335 / 277 / 253 / 218
BLDC With Axial Type Fan (1)
30
0.13
ASP-MO-UNIV 110-250
CKN-250
25 foot: SLS2506
50 foot: SLS5006
ETL & AHRI 5710082
5 years compressor, 1 year parts, 90 day limited labor
QS12-VJ220/VP220
1 of 2
Wall Mounted, Single Zone, Split System
QS12-VJ220
QS12-VP220
33.4 X 23.2 X 12.6
Page view 0
1 2

Summary of Contents

Page 1 - # eludehcSnoitangiseD tinU

• Electro-static, washable, main filter as standard• Low ambient control built in• The outdoor unit shall supply power to the indoor unitConstruction•

Page 2 - QS12-VJ220/VP220

SUBMITTALPage33 1/4"7 1/16"10 7/8"Ø2 1/4"Ø2 1/4"QS12-VJ220/VP2202 of 2Wall Mounted, Single Zone, Split System10” 30”33.4”12.

Comments to this Manuals