Page view 9
E-10
INSTALLING THE AIR CONDTIONER
Installing and Connecting the Drain Hose of the Indoor Unit
When installing the drain hose for the indoor unit, check if condensation draining is adequate.
When passing the drain hose through the 65-mm hole drilled in the wall, check the following:
Drain hose installation:
1
If necessary, connect the 6.6 ft (2m) extension drain hose to the drain hose.
2
If you use the extension drain hose, insulate the inside of the extension drain
hose with a shield.
3
Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain
hose tightly with a clamp.
If you don’t use the other drain hose hole, block it with a rubber stopper.
4
Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
5
Pass the drain hose through the hole in the wall. Check if it slants downwards
as seen in the picture.
The hose will be fixed permanently into position after finishing
the installation and the gas leak test; refer to page 14 for further details.
Shield
Drain hose Extension drain hose
The hose must
NOT slant upwards.
The end of the drain
hose must NOT be
placed under water.
Do NOT bend the hose
in different directions.
Keep a clearance of
at least 2inch (50mm)
between the end of the
hose and the ground.
Do NOT place the end
of the drain hose in a
hollow.
2inch
(50mm)
less
Ditch
Vivace1,2_KCV_Inv_DB98-27560A_IM_E.indd 10 2007-3-13 18:51:41