DPW Dip Switch Settings
Depending on the application of the DPW unit it may be necessary to alter the
Dip Switch settings from the standard positions
The unit has 5 Dip Switches located on the Microprocessor
Dip Switch Standard Setting Controls
1 ON Fuel Gas Type
2 OFF Fuel Gas Type
3 OFF Unit Options
4 OFF Forced Minimum Firing rate
5 OFF Forced Maximum Firing rate
Setting for Natural Gas Operation
Dip Switch Setting for NG
1 ON
2 OFF
Setting for LP Gas Operation
Dip Switch Setting for LP
1 OFF
2 ON
Unit Options
Switch Dip Switch #3 to ON
On DSR-100F press the Timers and Anti Freeze buttons simultaneously for 5
seconds. This will allow unit to enter the programming mode
Temperature display can be changed between DegF and DegC by pressing the
Timer button 3 times until Lc is displayed in the top RH corner of the unit display,
and f is displayed in the center of the screen
Press the Up temperature arrow and the f will change to a c
Hit the Power On/Off button to exit and switch Dip Switch #3 to OFF, the unit will
now display in DegC